Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.848
Filtrar
1.
Head Neck ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576171

RESUMO

We report the case of a laryngectomized patient with an enlarged tracheoesophageal puncture (TEP) that is refractory to standard treatments and culminating in life-threatening recurrent dislodgement and aspiration of custom fabricated dual extra-large flange voice prostheses (VP). The fabrication and use of a novel intraluminal prosthetic device to prevent dislodgement, lessen aspiration, and preserve TE voice is described. A custom device insetting a commercial VP into the posterior wall of a LaryTube (coined "inset-VP") was devised with the primary goal of eliminating chronic VP dislodgement and lessening aspiration while maintaining TE voice. Tools required to fabricate the device included a commercial laryngectomy tube, standard-flanged commercial indwelling voice prosthesis, felt-tip marker, 6 mm biopsy punch, and silk suture. After 7 months of using an inset-VP LaryTube device, the patient has experienced zero episodes of VP aspiration. Thin liquid aspiration control is equivalent or better than prior management with custom 24-30 mm dual collar prostheses. TEP voice is fluent and functional with device in place. Novel strategies are needed to manage the rare but devastating effects of a severely enlarged TEP. Solutions to manage symptoms need to be patient-specific, aligning with their anatomy, physiology, psychosocial needs, and goals. The inset-VP device described in this report may offer improved prosthetic retention in select patients with enlarged TE puncture and frequent VP dislodgements.

2.
J Pharm Bioallied Sci ; 16(Suppl 1): S792-S793, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595421

RESUMO

Objective: The current research was done to assess microbial seepage of two types of internal implant-abutment connections. Materials and Methods: Twenty dental implants are categorized into two groups. Group A fixtures with an internal hexagonal geometry and group B fixtures with a tri-lobe internal connection. All implant-abutment assemblies underwent a three-week incubation period at 37°C in sterile tubes containing 5 mL of Staphylococcus aureus broth culture. Through the use of Gram stain and biochemical processes, the resultant colonies were recognized. Results: The mean Log10 colony forming unit (CFU) in group A was 8.4 and in group B was 7.2. The variation between both groups was found to be considerable (P < 0.05). Microgap was more in group B compared to group A. Conclusion: Bacteria may infiltrate the small area between the implant and the abutment. Compared to dental implant fixtures with a tri-lobe internal connection, there was a noticeably higher Log10 CFU in dental implant fixtures with an internal hexagonal geometry.

3.
Surg Endosc ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594365

RESUMO

BACKGROUND: Indocyanine green fluorescence angiography (ICG-FA) may reduce perfusion-related complications of gastrointestinal anastomosis. Software implementations for quantifying ICG-FA are emerging to overcome a subjective interpretation of the technology. Comparison between quantification algorithms is needed to judge its external validity. This study aimed to measure the agreement for visceral perfusion assessment between two independently developed quantification software implementations. METHODS: This retrospective cohort analysis included standardized ICG-FA video recordings of patients who underwent esophagectomy with gastric conduit reconstruction between August 2020 until February 2022. Recordings were analyzed by two quantification software implementations: AMS and CPH. The quantitative parameter used to measure visceral perfusion was the normalized maximum slope derived from fluorescence time curves. The agreement between AMS and CPH was evaluated in a Bland-Altman analysis. The relation between the intraoperative measurement of perfusion and the incidence of anastomotic leakage was determined for both software implementations. RESULTS: Seventy pre-anastomosis ICG-FA recordings were included in the study. The Bland-Altman analysis indicated a mean relative difference of + 58.2% in the measurement of the normalized maximum slope when comparing the AMS software to CPH. The agreement between AMS and CPH deteriorated as the magnitude of the measured values increased, revealing a proportional (linear) bias (R2 = 0.512, p < 0.001). Neither the AMS nor the CPH measurements of the normalized maximum slope held a significant relationship with the occurrence of anastomotic leakage (median of 0.081 versus 0.074, p = 0.32 and 0.041 vs 0.042, p = 0.51, respectively). CONCLUSION: This is the first study to demonstrate technical differences in software implementations that can lead to discrepancies in ICG-FA quantification in human clinical cases. The possible variation among software-based quantification methods should be considered when interpreting studies that report quantitative ICG-FA parameters and derived thresholds, as there may be a limited external validity.

4.
J Gastrointest Surg ; 28(4): 351-358, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38583883

RESUMO

BACKGROUND: Anastomotic leakage (AL) is a determining factor of morbidity and mortality after esophagectomy. Adequate perfusion of the gastric conduit is crucial for AL prevention. This study aimed to determine whether intraoperative angiography using indocyanine green (ICG) fluorescence improves the incidence of AL after McKeown minimally invasive esophagectomy (MIE) with gastric conduit via the substernal route (SR). METHODS: This retrospective cohort study included 120 patients who underwent MIE with gastric conduit via SR for esophageal cancer between February 2019 and April 2023. Of 120 patients, 88 experienced intraoperative angiography using ICG (ICG group), and 32 patients experienced intraoperative angiography without ICG (no-ICG group). Baseline characteristics and operative outcomes, including AL as the main concern, were compared between the 2 groups. In addition, the outcomes among patients in the ICG group with different levels of fluorescence intensity were compared. RESULTS: The ICG and no-ICG groups were comparable in baseline characteristics and operative outcomes. There was no significant difference between the 2 groups regarding the rate of AL (31.0% vs 37.5%; P = .505), median dates of AL (9 vs 9 days; P = .810), and severity of AL (88.9%, 11.11%, and 0.0% vs 66.7%, 16.7%, and 16.7% for grades I, II, and III, respectively; P = .074). Patients in the ICG group with lower intensity of ICG had higher rates of leakage (24.6%, 39.3%, and 100% in levels I, II, and III of ICG intensity, respectively; P = .04). CONCLUSION: The use of ICG did not seem to reduce the rate of AL. However, abnormal intensity of ICG fluorescence was associated with a higher rate of AL, which implies a predictive potential.


Assuntos
Neoplasias Esofágicas , Verde de Indocianina , Humanos , Esofagectomia/efeitos adversos , Esofagectomia/métodos , Estudos Retrospectivos , Estômago/diagnóstico por imagem , Estômago/cirurgia , Estômago/irrigação sanguínea , Fístula Anastomótica/diagnóstico por imagem , Fístula Anastomótica/etiologia , Fístula Anastomótica/prevenção & controle , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/complicações , Imagem Óptica/métodos , Anastomose Cirúrgica/efeitos adversos
5.
Int J Colorectal Dis ; 39(1): 49, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38589520

RESUMO

PURPOSE: Anastomotic leakage after anterior resection for rectal cancer induces bowel dysfunction, but the influence on urinary and sexual function is largely unknown. This cross-sectional cohort study evaluated long-term effect of anastomotic leakage on urinary and sexual function in male patients. METHODS: Patients operated with anterior resection for rectal cancer in 15 Swedish hospitals 2007-2013 were identified. Anastomotic leakage and other clinical variables were retrieved from the Swedish Colorectal Cancer Registry and medical records. Urinary and sexual dysfunction were evaluated at 4 to 11 years after surgery using the International Prostate Symptom Score, International Index of Erectile Function, and European Organization for the Research and Treatment of Cancer Quality of Life Questionnaire CR29. The effect of anastomotic leakage on average scores of urinary and sexual dysfunction was evaluated as a primary outcome, and the single items permanent urinary catheter and sexual inactivity as secondary outcomes. The association of anastomotic leakage and functional outcomes was analyzed using regression models with adjustment for confounders. RESULTS: After a median follow-up of 84 months (interquartile range: 67-110), 379 out of 864 eligible men were included. Fifty-nine (16%) patients had anastomotic leakage. Urinary incontinence was more common in the leakage group, with an adjusted mean score difference measured by EORTC QLQ ColoRectal-29 of 8.69 (95% confidence interval: 0.72-16.67). The higher risks of urinary frequency, permanent urinary catheter, and sexual inactivity did not reach significance. CONCLUSION: Anastomotic leakage after anterior resection had a minor negative impact on urinary and sexual function in men.


Assuntos
Enteropatias , Neoplasias Retais , Humanos , Masculino , Fístula Anastomótica/etiologia , Fístula Anastomótica/cirurgia , Qualidade de Vida , Estudos Transversais , Neoplasias Retais/cirurgia , Estudos Retrospectivos , Anastomose Cirúrgica
6.
J Environ Manage ; 357: 120814, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38581896

RESUMO

Investigating the possible direction of a CO2-dissolved water plume migration near the potential CO2 leakage area is a significant task because it helps estimate the spatial and temporal monitoring scale to detect the signal of released CO2 from the storage. Accordingly, the Korea CO2 Storage Environmental Management (K-COSEM) research center tried to develop an intensive monitoring system and applied it to the artificial CO2 release test in the actual field. Monitoring data from the field tests depicted the horizontal movement of the CO2-dissolved water plume along the direction of the groundwater flow. However, it remains unclear how the CO2-dissolved water plume migrates vertically and how gas accumulation occurs near the capillary zone. The present study simulated the CO2 release test with a visual expression method utilizing a Hele-Shaw cell with hydraulic gradient conditions (i = 0, 0.1, and 0.01) and tried to estimate the significant influences on a diffusive-advective transport of the dissolved gas plume with the shallow aquifer condition. The visualization experiment results were intuitively verified to determine whether the theoretical principles of action related to plume flow applied in this context. The results suggest that a CO2-dissolved water plume is distributed by hydraulic gradients and density-driven CO2 convective flow. The plume shape, center, and area were analyzed using an image analyzer program; the results demonstrated that the plume characteristic evolved depending on the significant effects on the plume. When the plume was mainly affected by the hydraulic gradient, it rapidly moved from the injection point to the last boundary; in contrast, when it was influenced primarily by density-driven CO2 convective flow, it flowed diagonally downward in the shape of varied branches. The numerical model calculated the migration of the CO2-dissolved water plume affected by both factors. The laboratory experiment and numerical simulation results suggest that the migration of a CO2-dissolved water plume may be affected by the hydraulic gradient and density-driven CO2 convective transport. As such, these factors should be considered when designing and analyzing CO2 monitoring signals to detect CO2 leaks from shallow aquifer systems.


Assuntos
Água Subterrânea , Poluentes Químicos da Água , Dióxido de Carbono , Água , Simulação por Computador , Poluentes Químicos da Água/análise
7.
Khirurgiia (Mosk) ; (4): 82-92, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38634589

RESUMO

OBJECTIVE: To assess the possibilities of fluorescent detection system in qualitative and quantitative assessment of bowel perfusion in colorectal resections. MATERIAL AND METHODS: From May to August 2023, a single-center pilot cross-sectional unblinded study with inclusion of 18 patients with colon cancer (of left-sided - 12, of right-sided - 6, mean age - 72.9 years, m/w - 61/39%) was conducted. All patients underwent laparoscopic colorectal resections with extracorporeal stage of bowel transection. The evaluation of the bowel's ICG perfusion was conducted to assist in decision making about the level of its resection. Qualitative (visual) assessment was carried out in all 18 patients, in one patient twice, quantitative assessment of perfusion was conducted in 8 patients (left-sided resections - 6, right-sided hemicolectomy - 2). The qualitative evaluation was performed in real time on the analysis of the color gradient. The time parameters and fluorescence intensity at different level proximally and distally from the resection line were quantitatively estimated: Tstart - time of occurrence of minimal fluorescence in the areas of interest after the ICG injection (sec); Tmax - time to achieve maximum fluorescence intensity after the ICG injection (sec); Tmax-start - time interval between Tstart and Tmax, Imax - level of maximum fluorescence intensity (I). RESULTS: Visual qualitative analysis of fluorescence revealed unsatisfactory perfusion characteristics (black, dark-gray color) in the area planned by the surgeon to anastomose the bowel in 3 of 18 patients (16.6%). When analyzing the quantitative data of this group of patients, there was a 2-6-fold decrease in Imax level, and one patient had an increase in Tmax-start at the level of intended resection compared to the bowel's sections in the favorable zone. In all cases, the final bowel transection was conducted in the area of good perfusion. There was no clinical evidence of anastomotic dehiscence in the study group. CONCLUSION: Intraoperative evaluation of bowel perfusion is an important component of safe anastomosis formation in colorectal surgery. The use of ICG-FA allows to conduct qualitative and quantitative assessment of tissue perfusion of the bowel in order to assist in making intraoperative decisions. Quantitative evaluation of fluorescence provides more objective information about perfusion parameters. Imax and Tmax-start are the most promising quantitative indicators of local bowel's perfusion. Nevertheless, the precise interpretation of the quantitative indicators of ICG perfusion needs to be clarified.


Assuntos
Neoplasias Colorretais , Cirurgia Colorretal , Humanos , Anastomose Cirúrgica , Fístula Anastomótica/cirurgia , Colectomia , Neoplasias Colorretais/cirurgia , Estudos Transversais , Angiofluoresceinografia , Verde de Indocianina , Perfusão , Masculino , Feminino , Idoso
8.
J Surg Case Rep ; 2024(1): rjad709, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38576543

RESUMO

A defunctioning stoma is used to alleviate the consequences of anastomotic leakage after low anterior resection for rectal cancer. A loop ileostomy is often preferred but may lead to dehydration and kidney injury. Here, we present a case series for an alternative: the left-sided loop colostomy. A convenience sample of four patients underwent robotic low anterior resection for rectal cancer. A complete splenic flexure mobilization and a total mesorectal excision were performed. To defunction the anastomosis, the redundant left colon was brought up to a stoma site in the left iliac fossa and matured as a loop colostomy. Two patients experienced minor stoma leaks and one also had a small prolapse, while all patients had their colostomies reversed on average 7 months after surgery without complications. There were no dehydration episodes and creatinine levels remained within baseline levels at end of follow-up (on average 18 months).

9.
Int J Clin Exp Pathol ; 17(3): 72-77, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38577698

RESUMO

Bone cement leakage from the femoral medullary cavity is a rare complication following hip replacement. Currently, there are no reports of bone cement leakage into the heart. Here, we report an 81-year-old female patient with right femoral neck fracture. A thorough preoperative examination showed that bone cement had leaked into the heart during right femoral head replacement, leading to the death of the patient that night. Postoperative cardiac ultrasound showed that bone cement entered the vascular system through the femoral medullary cavity and subsequently entered the heart. Extreme deterioration in the patient's condition resulted in death that night. Unfortunately, the patient's family abandoned the idea of surgical removal of foreign bodies, leading to inevitable death. This case emphasizes the risk of clinical manifestations of cardiac embolism of bone cement after artificial femoral head replacement, suggesting that the risk of such embolism might be underestimated. We propose routine real-time C-arm X-ray guidance and injection of an appropriate amount of bone cement to prevent serious cardiopulmonary failure.

10.
Langenbecks Arch Surg ; 409(1): 124, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615148

RESUMO

PURPOSE: Gastrointestinal disorders frequently necessitate surgery involving intestinal resection and anastomosis formation, potentially leading to severe complications like anastomotic leakage (AL) which is associated with increased morbidity, mortality, and adverse oncologic outcomes. While extensive research has explored the biology of anastomotic healing, there is limited understanding of the biomechanical properties of gastrointestinal anastomoses, which was aimed to be unraveled in this study. METHODS: An ex-vivo model was developed for the biomechanical analysis of 32 handsewn porcine end-to-end anastomoses, using interrupted and continuous suture techniques subjected to different flow models. While multiple cameras captured different angles of the anastomosis, comprehensive data recording of pressure, time, and temperature was performed simultaneously. Special focus was laid on monitoring time, location and pressure of anastomotic leakage (LP) and bursting pressures (BP) depending on suture techniques and flow models. RESULTS: Significant differences in LP, BP, and time intervals were observed based on the flow model but not on the suture techniques applied. Interestingly, anastomoses at the insertion site of the mesentery exhibited significantly higher rates of leakage and bursting compared to other sections of the anastomosis. CONCLUSION: The developed ex-vivo model facilitated comparable, reproducible, and user-independent biomechanical analyses. Assessing biomechanical properties of anastomoses offers an advantage in identifying technical weak points to refine surgical techniques, potentially reducing complications like AL. The results indicate that mesenteric insertion serves as a potential weak spot for AL, warranting further investigations and refinements in surgical techniques to optimize outcomes in this critical area of anastomotic procedures.


Assuntos
Fístula Anastomótica , Mesentério , Animais , Suínos , Fístula Anastomótica/prevenção & controle , Anastomose Cirúrgica , Mesentério/cirurgia , Técnicas de Sutura , Cicatrização
11.
Surg Open Sci ; 19: 87-94, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38601735

RESUMO

Background: Evidence regarding the application of the multispectral camera for blood flow measurement is insufficient, and its performance has not been compared with the conventional indocyanine green (ICG) method. Therefore, we retrospectively compared the effectiveness of a new multispectral camera for non-invasive, real-time, quantitative imaging of tissue oxygen (O2) saturation and hemoglobin (Hb) levels and commercially available ICG fluorescence imaging in hemodynamic assessment of gastric tubes in esophagectomy. Methods: Thirty patients who underwent thoracoscopic esophagectomy and gastric tube reconstruction for esophageal cancer were included in this study. The multispectral camera was used to measure tissue O2 saturation and Hb levels. The ICG fluorescence imaging, with the analysis software tool Lumi view, was employed to record ICG luminance changes, with values measured at the anastomotic site. Furthermore, the usefulness of each assessment device was examined using the arterial and venous blood flow indices as cutoff lines for cases with anastomotic failure. Results: In the evaluation of arterial perfusion, anastomotic leak occurred in three of the five (60 %) patients with arterial insufficiency as assessed by the ICG imaging, while anastomotic leakage occurred in all three patients (100 %) who were assessed as having arterial insufficiency by the multispectral camera. In the evaluation of venous perfusion, anastomotic leakage occurred in three of the nine (33.3 %) patients diagnosed with venous stasis by the IC imaging and in three of the five (60 %) patients assessed by the multispectral camera. Conclusion: The multispectral camera assessed gastric tube blood flow more accurately than the ICG fluorescence method.

12.
Nanomicro Lett ; 16(1): 171, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38602570

RESUMO

Although covalent organic frameworks (COFs) with high π-conjugation have recently exhibited great prospects in perovskite solar cells (PSCs), their further application in PSCs is still hindered by face-to-face stacking and aggregation issues. Herein, metal-organic framework (MOF-808) is selected as an ideal platform for the in situ homogeneous growth of a COF to construct a core-shell MOF@COF nanoparticle, which could effectively inhibit COF stacking and aggregation. The synergistic intrinsic mechanisms induced by the MOF@COF nanoparticles for reinforcing intrinsic stability and mitigating lead leakage in PSCs have been explored. The complementary utilization of π-conjugated skeletons and nanopores could optimize the crystallization of large-grained perovskite films and eliminate defects. The resulting PSCs achieve an impressive power conversion efficiency of 23.61% with superior open circuit voltage (1.20 V) and maintained approximately 90% of the original power conversion efficiency after 2000 h (30-50% RH and 25-30 °C). Benefiting from the synergistic effects of the in situ chemical fixation and adsorption abilities of the MOF@COF nanoparticles, the amount of lead leakage from unpackaged PSCs soaked in water (< 5 ppm) satisfies the laboratory assessment required for the Resource Conservation and Recovery Act Regulation.

13.
Neurosurg Rev ; 47(1): 161, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38625461

RESUMO

OBJECTIVE: Chronic subdural hematoma (CSDH) is frequently met in neurosurgical practice and often need urgent surgical treatment in case of neurological deterioration. Different surgical approaches to evacuate CSDH are described in the literature. In our experience, an external drainage system is crucial in order to avoid recurrences. We recently encountered a case of subcutaneous CSF collection after drainage removal. Thus, we developed a simple surgical technique to prevent postoperative CSF leak after subdural drainage system removal. METHOD: We have developed a technique in which the periosteum is harvested during the surgery prior to the evacuation of the hemorrhage and fixed with sutures on the uncut dura mater opposite and laterally to the exit of the catheter exiting the dural hole caused by the passage of the Jackson-Pratt subdural drainage system. When the drainage catheter is removed, the flap, partially held by the sutures, falls over the hole avoiding CSF leakage. By using this technique, the small dural hole will be covered with the periosteum allowing for natural closure and wound healing hence preventing CSF leakage. RESULTS: This technique was successfully employed in 21 patients who didn't develop postoperative CSF leakage following CSDH evacuation and removal of subdural drainage system. CONCLUSION: In this technical note, we describe a safe dura closure technique that we developed to help reduce the risk of postoperative CSF leakage following subdural drainage removal, which can, however, also be applied in all surgeries in which a catheter is placed in the subdural space.


Assuntos
Hematoma Subdural Crônico , Humanos , Hematoma Subdural Crônico/cirurgia , Drenagem , Vazamento de Líquido Cefalorraquidiano/prevenção & controle , Vazamento de Líquido Cefalorraquidiano/cirurgia , Dura-Máter/cirurgia , Período Pós-Operatório
14.
Int J Colorectal Dis ; 39(1): 53, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38625550

RESUMO

BACKGROUND: Current evidence concerning bowel preparation before elective colorectal surgery is still controversial. This study aimed to compare the incidence of anastomotic leakage (AL), surgical site infections (SSIs), and overall morbidity (any adverse event, OM) after elective colorectal surgery using four different types of bowel preparation. METHODS: A prospective database gathered among 78 Italian surgical centers in two prospective studies, including 6241 patients who underwent elective colorectal resection with anastomosis for malignant or benign disease, was re-analyzed through a multi-treatment machine-learning model considering no bowel preparation (NBP; No. = 3742; 60.0%) as the reference treatment arm, compared to oral antibiotics alone (oA; No. = 406; 6.5%), mechanical bowel preparation alone (MBP; No. = 1486; 23.8%), or in combination with oAB (MoABP; No. = 607; 9.7%). Twenty covariates related to biometric data, surgical procedures, perioperative management, and hospital/center data potentially affecting outcomes were included and balanced into the model. The primary endpoints were AL, SSIs, and OM. All the results were reported as odds ratio (OR) with 95% confidence intervals (95% CI). RESULTS: Compared to NBP, MBP showed significantly higher AL risk (OR 1.82; 95% CI 1.23-2.71; p = .003) and OM risk (OR 1.38; 95% CI 1.10-1.72; p = .005), no significant differences for all the endpoints were recorded in the oA group, whereas MoABP showed a significantly reduced SSI risk (OR 0.45; 95% CI 0.25-0.79; p = .008). CONCLUSIONS: MoABP significantly reduced the SSI risk after elective colorectal surgery, therefore representing a valid alternative to NBP.


Assuntos
Fístula Anastomótica , Neoplasias Colorretais , Humanos , Estudos Prospectivos , Anastomose Cirúrgica , Fístula Anastomótica/etiologia , Aprendizado de Máquina , Neoplasias Colorretais/cirurgia , Itália/epidemiologia
15.
Fluids Barriers CNS ; 21(1): 35, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622710

RESUMO

Early breach of the blood-brain barrier (BBB) and consequently extravasation of blood-borne substances into the brain parenchyma is a common hallmark of ischemic stroke. Although BBB breakdown is associated with an increased risk of cerebral hemorrhage and poor clinical prognosis, the cause and mechanism of this process are largely unknown. The aim of this study was to establish an imaging and analysis protocol which enables investigation of the dynamics of BBB breach in relation to hemodynamic properties along the arteriovenous axis. Using longitudinal intravital two-photon imaging following photothrombotic induction of ischemic stroke through a cranial window, we were able to study the response of the cerebral vasculature to ischemia, from the early critical hours to the days/weeks after the infarct. We demonstrate that disruption of the BBB and hemodynamic parameters, including perturbed blood flow, can be studied at single-vessel resolution in the three-dimensional space as early as 30 min after vessel occlusion. Further, we show that this protocol permits longitudinal studies on the response of individual blood vessels to ischemia over time, thus enabling detection of (maladaptive) vascular remodeling such as intussusception, angiogenic sprouting and entanglement of vessel networks. Taken together, this in vivo two-photon imaging and analysis protocol will be useful in future studies investigating the molecular and cellular mechanisms, and the spatial contribution, of BBB breach to disease progression which might ultimately aid the development of new and more precise treatment strategies for ischemic stroke.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Barreira Hematoencefálica/metabolismo , Acidente Vascular Cerebral/metabolismo , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/metabolismo , Isquemia/metabolismo
16.
J Clin Med ; 13(7)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38610630

RESUMO

Background: Online hemodiafiltration (OHDF) has a lower mortality rate than hemodialysis (HD). We aimed to investigate the impact of the albumin leakage on the mortality of patients receiving HD or OHDF. Methods: In this single-center study, consecutive patients receiving renal replacement therapy between January and April 2018 were retrospectively registered. Using (1:1) propensity score matching, 3-year all-cause mortality was compared between patients receiving HD and OHDF, and the impact of albumin leakage on the mortality rate in both groups was investigated. Results: Of the 460 patients, 137 patients receiving HD were matched with an equal number of patients receiving OHDF. OHDF was associated with higher albumin leakage (p < 0.001) and a lower mortality than HD (log-rank test, p < 0.001). Albumin leakage was associated with mortality in patients receiving HD (per 1 g increase, hazard ratio (HR): 0.495, 95% confidence interval (CI): 0.275-0.888) and patients receiving OHDF (per 1 g increase, HR: 0.734, 95% CI: 0.588-0.915). Patients receiving HD, with the highest albumin leakage tertile (>3 g), had a similar mortality rate to patients receiving OHDF, with similar albumin leakage. Conclusions: The negative relationship between albumin leakage and mortality suggests the benefit of removing middle- to -large-molecular-weight substances to improve survival.

17.
Surg Endosc ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38619559

RESUMO

BACKGROUND: Intracorporeal mechanical gastrogastrostomy (IMG) techniques have recently been developed and their short-term safety was presented in their initial evaluation. However, whether they are comparable to extracorporeal hand-sewing gastrogastrostomy (EHG) remains unclear. The aim of the study is to establish the safety of IMG in totally laparoscopic pylorus-preserving gastrectomy (TLPPG) compared to EHG in laparoscopy-assisted pylorus-preserving gastrectomy (LAPPG). METHODS: We retrospectively analyzed the short-term outcomes of patients with middle-third early gastric cancer who underwent LAPPG or TLPPG between 2005 and 2022. The primary objective of this study was to evaluate the non-inferiority of IMG to EHG in terms of safety, with the primary endpoint being the risk difference in anastomosis-related complications (ARCs). The sample size required to achieve a statistical power of 80% for the non-inferiority test was 971 with a one-sided alpha level of 5% and non-inferiority of 5%. RESULTS: The analysis included a total of 1,021 patients who underwent LAPPG or TLPPG during the study period. Among them, 488 patients underwent EHG, while 533 underwent IMG. The incidences of ARCs were 11.3% and 11.4% in EHG and IMG, respectively. The observed difference in incidence was 0.0017 (90% confidence interval - 0.0313 to 0.0345), which statistically demonstrated the non-inferiority of IMG to EHG in the incidence of ARCs. Among other complications, the incidence of wound infection in IMG was lower than that in EHG. CONCLUSION: IMG is safe regarding ARCs compared with EHG. These results will encourage surgeons to introduce IMG for patients with early middle gastric cancer.

18.
Asian J Surg ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38604851

RESUMO

OBJECTIVE: To investigate the effectiveness of the original oblique conformal anastomosis presented in this research in reducing the incidence of cervical anastomotic leak after performing totally minimally invasive esophagectomy (TMIE). METHODS: The esophagus and stomach of 27 fresh pigs, termed the esophagogastric model, were used to simulate human esophagogastric organs for this study's in vitro experimental objectives. Nine esophagogastric models of similar weight were divided into three groups. Esophagogastrostomy with circular-stapled end-to-side anastomosis was performed. A tension gauge was used to pull the anastomosis, and the tension at which anastomotic leakage occurred was recorded. Furthermore, a retrospective assessment of 539 patients who underwent TMIE was conducted to analyze the influencing factors of cervical anastomotic leakage. RESULTS: Experiments on the esophagogastric models showed a higher fracture strength of oblique conformal anastomosis than that of conventional anastomosis (F2,18 = 40.86, P < 0.05), which was associated with a lower incidence of cervical anastomotic leakage (X2 = 9.0260, P = 0.0027). Retrospective analysis of 539 esophageal cancer patients who underwent TMIE showed that in contrast to conventional anastomosis, oblique conformal anastomosis was an independent protective factor against cervical anastomotic leakage (P = 0.0462, OR = 0.5872, 95% CI = 0.3497-0.9993). CONCLUSION: Oblique conformation anastomosis was stronger and involved a more prominent reduced risk of cervical anastomotic leakage than conventional anastomosis after TMIE.

19.
J Cardiothorac Surg ; 19(1): 240, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632619

RESUMO

BACKGROUND: Chylous leakage is a rare complication following esophagectomy; however, it can lead to mortality. We aimed to systematically evaluate the factors that may lead to increased chylous leakage after esophagectomy. METHODS: Three databases (PubMed, Embase, and Cochrane Library) were systematically searched for all studies investigating the occurrence of chylous leakage after esophagectomy. RESULTS: A total of 32 studies were identified, including 26 randomized controlled trials and 3 cohort and case-control studies, each. The overall incidence of chylous leakage was 4.7% (278/5,971 cases). Analysis of preoperative, intraoperative, and postoperative factors showed that most of the qualitative analysis results did not significantly increase the incidence of chylous leakage. In some quantitative analyses, the chylous leakage rate was significantly lower in the thoracic duct mass ligation group than in the conservative treatment group (relative risk [RR] = 0.33; 95% confidence interval [CI], 0.13-0.83; I2 = 0.0%; P = 0.327). Direct oral feeding significantly reduced chylous leakage compared with jejunostomy (RR = 0.06; 95% CI 0.01-0.33; I2 = 0.0%; P = 0.335). However, preoperative inspiratory muscle training (RR = 1.66; 95% CI, 0.21-12.33; I2 = 55.5%; P = 0.134), preoperative chemoradiotherapy (RR = 0.99; 95% CI, 0.55-1.80; I2 = 0.0%; P = 0.943), and robotic assistance (RR = 1.62; 95% CI, 0.92-2.86; I2 = 0.0%; P = 0.814) did not significantly reduce the incidence of chylous leakage. CONCLUSIONS: Ligation of the thoracic duct and direct oral feeding can reduce the incidence of chylous leakage after esophagectomy in patients with esophageal cancer. Other contributing factors remain unclear and require validation in further high-quality studies.


Assuntos
Neoplasias Esofágicas , Esofagectomia , Humanos , Esofagectomia/métodos , Neoplasias Esofágicas/cirurgia , Ducto Torácico/cirurgia , Ligadura/métodos , Quimiorradioterapia , Complicações Pós-Operatórias/epidemiologia
20.
Cureus ; 16(3): e56415, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38638760

RESUMO

Introduction Anastomotic leakage is a serious complication in colon and rectal cancer surgeries, contributing to increased mortality rates and extended hospital stays. Despite various preventive measures, including intraoperative assessments and transanal drains, the incidence of anastomotic leakage remains a significant concern. This study investigates the potential efficacy of polyglycolic acid (PGA) sheets in reducing anastomotic leakage rates in gastrointestinal surgeries. Materials & methods A retrospective cohort study was conducted between January 2021 and January 2023 at Nagoya Tokushukai General Hospital, Ogaki Tokushukai Hospital, and Haibara General Hospital. A total of 239 patients undergoing colon or rectal cancer surgery were included. Anastomoses were performed with or without PGA sheets, and groups were compared using statistical analyses, including t-tests, Mann-Whitney U tests, and chi-square tests. The primary endpoint was the incidence of anastomotic leakage. Results Of the 239 patients, anastomotic leakage occurred in 14 (6%). The PGA use group (52 patients) showed no instances of anastomotic leakage while the PGA non-use group (187 patients) had 14 cases. Comparisons revealed significant differences in anastomotic leakage rates (p=0.04) between the two groups. Univariate analysis demonstrated a lower incidence of anastomotic leakage associated with PGA use (p=0.04). However, no significant differences were observed for transanal drainage (p=0.66), smoking (p=0.76), steroid use (p=1), and preoperative chemotherapy (p=0.07). Conclusion This study suggests that the use of PGA sheets in gastrointestinal anastomosis may contribute to a lower incidence of anastomotic leakage. The findings highlight the need for further prospective studies with a larger sample size, distinguishing between colon and rectum surgeries. Despite the limitations of this retrospective study, the observed reduction in anastomotic leakage frequency with PGA sheet use is noteworthy, emphasizing the potential significance of this approach in preventing a critical complication in colorectal surgeries.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...